w house 25 800x510crp Energy Usage & Sustainability (SANS 10400X & XA)

Glazing and lighting are two vital factors when it comes to energy usage.

In 2011, in an endeavour to make our buildings more sustainable, and to decrease energy usage in South Africa, a new part was added to SANS 10400, The application of the National Building Regulations. Part X deals with environmental sustainability, and Part XA deals with energy usage in buildings.

In many ways these new regulations have turned the building industry upside down, but not in a bad way. However for the average man-in-the-street it has become a puzzle of note. Every week we get people writing into this web site asking for advice and information about the “new energy laws” and how they affect their building and renovations.

On the down side, it seems that new regulations have opened up a can of worms that has less-than-knowledgable people (and some scamsters) flippantly quoting “the new green laws” in an effort to force people to spend more money than they need to on energy-efficient materials, appliances and the like. While there is no doubt that we need to “go green” and get our act together (pun intended) in terms of energy efficient building, it is also important to know the difference between what we should do, and what we must do to comply with the National Building Regulations and other national standards.

What the National Building Regulations and Building Standards Act Says

While the Act was originally passed in 1977 (officially it’s Act 103 of 1977), a number of amendments have been added to it over time. In 2011, Rob Davies, the Minister of Trade and Industry added the sections that relate to environmental sustainability and to energy usage in buildings.

The motivation for this amendment is to reduce greenhouse gases caused by buildings and extensions to buildings. These relate to a number of specific occupancies that are defined in Part A of SANS 10400, namely:

  • A1 - Entertainment and public assembly Occupancy where persons gather to eat, drink, dance or participate in other recreation.
  • A2 - Theatrical and indoor sport Occupancy where persons gather for the viewing of theatrical, operatic, orchestral, choral, cinematographical or sport performances.
  • A3 - Places of instruction Occupancy where school children, students or other persons assemble for the purpose of tuition or learning.
  • A4 - Worship  Occupancy where persons assemble for the purpose of worshipping.
  • C1 - Exhibition hall Occupancy where goods are displayed primarily for viewing by the public.
  • C2 - Museum Occupancy comprising a museum, art gallery or library.
  • E1 - Place of detention Occupancy where people are detained for punitive or corrective reasons or because of their mental condition.
  • E2 - Hospital Occupancy where people are cared for or treated because of physical or mental disabilities and where they are generally bedridden.
  • E4 - Health care Occupancy which is a common place of long term or transient living for a number of unrelated persons consisting of a single unit on its own site who, due to varying degrees of incapacity, are provided with personal care services or are undergoing medical treatment.
  • F1 - Large shop Occupancy where merchandise is displayed and offered for sale to the public and the floor area exceeds 250 m2.
  • F2 - Small shop Occupancy where merchandise is displayed and offered for sale to the public and the floor area does not exceed 250 m2.
  • F3 - Wholesalers’ store Occupancy where goods are displayed and stored and where only a limited selected group of persons is present at any one time.
  • G1 - Offices Occupancy comprising offices, banks, consulting rooms and other similar usage.
  • H1 - Hotel Occupancy where persons rent furnished rooms, not being dwelling units.
  • H2 - Dormitory Occupancy where groups of people are accommodated in one room.
  • H3 - Domestic residence Occupancy consisting of two or more dwelling units on a single site.
  • H4 - Dwelling house Occupancy consisting of a dwelling unit on its own site, including a garage and other domestic outbuildings, if any.
  • H5 - Hospitality Occupancy where unrelated persons rent furnished rooms on a transient basis within a dwelling house or domestic residence with sleeping accommodation for not more than 16 persons within a dwelling unit.

But they specifically EXCLUDE garage and storage areas contained within these specified occupancies, as well as a number of other buildings that are used for commercial, industrial and buildings used exclusively for a variety of storage uses.

The law (because this is part of the Act – not SANS 10400) states that these “occupancies” (types of buildings) must be:

  • capable of using energy efficiently while fulfilling user-needs in relation to various things including thermal comfort, lighting and hot water; OR
  • have a “building envelope and services” that facilitate the efficient use of energy that is appropriate to the function and use of the building as well as its geographical location and its internal environment.

So it is not a one solution fits all situation. For instance, what works for a house in Durban may not make the same structure energy efficient in Cape Town! In addition, the legislation excludes the “equipment and plant” required for conducting business – if the building is used for business.

Hot Water Heating Requirements

XA2 requires that at least a half – “50% (volume fraction) of the annual average hot water heating requirement shall be provided by means other than electrical resistance heating including but not limited to solar heating, heat pumps, heat recovery from other systems or processes and renewable combustible fuel”.

So you can use a conventional geyser IF you meet the 50% requirement. And if you are renovating, you certainly don’t have to toss all your existing water equipment and go solar – even though there is absolutely no doubt that it’s the way to go.

What is Required

The orientation, shading, services and building envelope must be designed according to SANS 10400 Part XA. Alternatively the rational design of the building must be done by a competent person who “demonstrates that the energy usage of such building is equivalent to or better than that which would have been achieved by compliance with the requirements of SANS XA, or has a theoretical energy usage performance, determined using certified thermal calculation software, less than or equal to that of a reference building in accordance with SANS 10400 Part XA”.

If you’re looking to change jobs, becoming a person competent to specify these requirements is one way to go! It is something that is not easy for someone who hasn’t got the relevant training to get their head around.

What 10400 XA Says

As with all national standards, 10400 XA has a number of definitions, some of which are in the glossary that is part of the Act.

A few of the important definitions that relate to this particular part of the standard are:

  • Building envelope Elements of a building that separate a habitable room from the exterior of a building or a garage or storage area 
  • Competent person Person who is qualified by virtue of his education, training, experience and contextual knowledge to make a determination regarding the performance of a building or part thereof in relation to a functional regulation or to undertake such duties as may be assigned to him in terms of the National Building Regulations
  • Fenestration Any glazed opening in a building envelope, including windows, doors and skylights
  • Fenestration area Area that includes glazing and framing elements that are fixed or movable, and opaque, translucent or transparent

Requirements of 10400 XA

The requirements of this new national standard cover:

  1. Hot water supply
  2. Energy usage and building envelope
  3. Design assumptions
  4. Building envelope requirements

The standard also defines the different climatic zones of South Africa.Climate zones XA1 Energy Usage & Sustainability (SANS 10400X & XA)

To be a little more specific, the main centres for each zone are:

  • Zone 1 – Johannesburg and Bloemfontein
  • Zone 2 – Pretoria and Polokwane
  • Zone 3 – Makhado and Nelspruit
  • Zone 4 – Cape Town and Port Elizabeth
  • Zone 5 – Durban, Richards Bay and East London
  • Zone 6 – Kimberley and Upington

Building Envelope Requirements

This is probably the most vital part of the new regulation, and it addresses orientation, floors, external walls, fenestration, and roof assemblies – but not in a lot of detail.

Floors

If any type of underfloor heating system is used in a home, this must be insulated under the concrete slab with insulation that has a minimum R-value of at least 1,0. The R-value is the thermal resistance (square metre K/W) of a component. According to the Standard, it is “the inverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces, under steady state conditions, per unit area”.

Roof Assemblies

Any roof assembly must achieve a minimum R-value for the direction of heat flow. This is specified in several tables in the regulations.

 Minimum total R-values of roof assembliesPart XA Min total R values of roof assemblies Energy Usage & Sustainability (SANS 10400X & XA)

Roofs with metal sheeting affixed to purlins, rafters or battens made of metal are required to have a thermal break that consists of a material with an R-value that is not less than 0,2, and which is installed between the sheeting and the support. In addition, roofing assemblies that utilize metal sheeting must achieve a minimum total R-value that meets the requirements shown in the table above. Insulation must also be installed with an R-value that meets the specified in the table below.

Metal sheeting roof assembliesPart XA Metal sheeting roof assemblies Energy Usage & Sustainability (SANS 10400X & XA)

Clay tiles used for roofing must achieve a minimum R-value as in the first table above. Insulation should be in accordance with the specifications shown below.

Part XA Clay tile roof assemblies Energy Usage & Sustainability (SANS 10400X & XA)

The other standard that you need to know about is
SANS 204 (2011): Energy efficiency in buildings.  

 

Mar 112013
 

Fenestration and Glazing Guidelines, Procedures and Calculations.

Windows house335 Fenestration Calculations

The guidelines featured in the pdf below give an idea to anyone wanting to calculate the Fenestration Compliance Procedures in terms of Sans 10400-XA:2011 and SANS 204:2011, what is required and what is involved.

There is a step-by-step guide to area (nett floor) calculation with reference to the parts of the regulations that apply. A SGHC (solar heat gain calculator) is also supplied, to calculate the heat conducted in and out of a building. There are a couple of “real life” calculations at the end of the document that illustrate how this was achieved.

You will see that the calculations that need to be done to comply with the Regulations are not at all straightforward. But you do, in any case require a “competent person” to draw up your building plans, submit them to the local authority, and take responsibility for the project (including ensuring that construction is in accordance with the plans). A competent person should be well equipped to interpret fenestration and glazing guidelines as well as procedures and the calculations. If not, it is the responsibility of that person to include someone who is in the project.

Download (PDF, 250KB)

Nov 152011
 
Glazing366 Glazing

All forms of glazing need to comply with the relevant SANS.

Glazing and the Glass you use for it

The section on glazing in the National Building Regulations & Building Standards Act is short and reasonably sweet.

Essentially you need to be sure that any material used for glazing in buildings is secure and durable and that it is fixed so that it:

  • safely sustains wind actions that one would normally expect wherever you live in South Africa (but not necessarily major hurricanes or tornadoes that might be experienced in other parts of the world),
  • does not allow water to penetrate the interior of the building, and
  • is obvious to anyone who approaches it (if it isn’t, people could walk right into the glass and be injured, particularly if it is completely transparent and not made of “safety glass”).

Of course it isn’t only glass that we use for glazing. There are also a number of plastic and polycarbonate materials, as well as organically-coated glass, which can be used.

When it comes to choosing the best type of glazing for the job, the essential aspect is to make sure that if someone (or an animal) does impact the glazing – or collide with it, they won’t be seriously hurt. Factors to take into account include:

  • the position of the glazing,
  • the number of people who are likely to be able to access the glazed door or window, and
  • the probably behaviour patterns of anyone (or anything) that is likely to get close to the glazed area.

And ultimately, as long as the glazing material is selected, fixed and marked in accordance with SABS 10400-N, all should be well and legal… and safe for all concerned.

NBR Changes that Relate to Glazing

The “new” National Building Regulations are a lot more specific in terms of glazing installations than they were previously. Not only is the maximum pane area and glass thickness specified, but so too are the different types of glass. These are:

  • monolithic annealed glass,
  • patterned annealed and wired glass,
  • laminated annealed safety glass,
  • toughened safety glass.

In addition to this, glass must also comply with the relevant SANS, as must the method of fitting the glass or alternative material used for glazing.

Just be aware that whether you are glazing doors, windows, shower cubicles, shop-fronts or anything else, glazing MUST comply with SANS 10400-N as well as other standards that relate to the manufacture of glazing materials.

Construction Standards of Glazing

The SABS also has a strategic policy that relates to glazing in buildings. The reason for this is to standardize glazing in buildings in terms of:

  • terminology (so that we all understand exactly what the regulations mean and relate to),
  • performance requirements,
  • various methods of calculation,
  • design and construction guidelines,
  • the classification and specification of materials (including dimensional properties).

To this end, the SABS has a sub-committee that specifically develops, maintains and co-ordinates standards in the field of glazing materials that are used in buildings. The committee’s responsibility is to:

  • develop national standards,
  • participate in the development of standards (getting votes, comment and so on),
  • develop and review the programme of work,
  • recommend what else needs to be done to ensure that the South African standards stay on track with international standards.

At the end of the day, the safety of users and installers is paramount.

Here is a drawing from the Standard that provides guidance

Part N Safety Glazing Glazing

Examples of safety glazing requirements for exterior doors and windows.